A Service of the Hamilton Regional Laboratory
Laboratory Test Information
Committed to Quality
The HRLMP is committed to providing high quality laboratory results for our clients.
As one of the largest integrated laboratory medicine programs in Canada we strive to produce the right results the first time on every sample we receive.
Test Name:
Epstein Barr Virus Quantitative PCR
Alternate Name(s): EBV Viral Load,
Quantitative EBV PCR

Requisition Form: Download requisition form for: R_708112 (2025-12-09) - LRC Microbiology Requisition - Update - Fillable.pdf
Specimen Requirement: 1 mL EDTA Plasma
Paediatric/Neonatal collection: 1 mL EDTA Plasma

Specimen Handling Instructions:
Freeze and ship frozen on dry ice. Collect Monday through Thursday only.
FOR TRANSPLANT PATIENTS ONLY.

Reference Interval: EBV DNA: < 500 copies/mL plasma. Below detection limit of assay.
Turnaround Time: 7 days
Interpretive Comments:
ear47mtete|20504125C0E0|LRCTEST_background|InterpretiveComments|Comments|0xffffb782010000001701000001001e00
Detection Limit: 500 copies/mL plasma.

Linear Range: from 1000 copies/mL to approx. 1 x 100,000,000 copies/mL .

For results within the linear range of the assay, viral load will be provided in copies/mL and log 10 copies/mL.

An increase or decrease of one log in viral load may be significant.

Method of Analysis: Artus EBV RG Kit
Test was Last Updated: 1/14/2026
Testing Laboratory: Molecular Microbiology
Testing Site: SJHH